Lead time if the product is out of stock (business days):
35KEM Küppers Series VTC/VIC
• Compact on-site display with carrier frequency or inductive sensor for the evaluation of volume flows.
• A temperature sensor integrated into the sensor tip is available in the VTC version, thereby making it possible to measure the medium temperature.
• All measurement results and parameters relevant for the process can be shown directly on the VTC/VIC via the graphic display (that can be illuminated) and changed using the four membrane keys.
• 3 linearization banks with 20 points each are available to improve the accuracy. They are used tl, fixed assignment).
• In pure 2-conductor operation (4 - 20 mA) the instantaneous value (flow) is dimensionally output on the current loop according to the programming.
• A programmable digital output and a maximum of two control inputs (see technical data) are available in addition for further processing and control.
• The VTC/VIC has an interface that allows operating parameters to be set and measured values to be read with the help of the CON.USB interface adapter and the “KEM EasyControl” visualization software. Optionally this interface can also be carried out as HART or USB.
• Depending on the version, the electrical connection is realized via a plug connector or a screw terminal strip that is exposed when the front cover is flipped open and then linearizes the measurement signal depending on the chosen operating mode (external control).
• Compact on-site display with carrier frequency or inductive sensor for the evaluation of volume flows.
• A temperature sensor integrated into the sensor tip is available in the VTC version, thereby making it possible to measure the medium temperature.
• All measurement results and parameters relevant for the process can be shown directly on the VTC/VIC via the graphic display (that can be illuminated) and changed using the four membrane keys.
• 3 linearization banks with 20 points each are available to improve the accuracy. They are used tl, fixed assignment).
• In pure 2-conductor operation (4 - 20 mA) the instantaneous value (flow) is dimensionally output on the current loop according to the programming.
• A programmable digital output and a maximum of two control inputs (see technical data) are available in addition for further processing and control.
• The VTC/VIC has an interface that allows operating parameters to be set and measured values to be read with the help of the CON.USB interface adapter and the “KEM EasyControl” visualization software. Optionally this interface can also be carried out as HART or USB.
• Depending on the version, the electrical connection is realized via a plug connector or a screw terminal strip that is exposed when the front cover is flipped open and then linearizes the measurement signal depending on the chosen operating mode (external control).
Series | VTC/VIC |
---|---|
Product type | Local display |
Brand | KEM Küppers |